PRODUCT MODEL NUMBERS
UXT2030AY UXT2036AY
Electrical: A 120 volt, 60 Hz, AC only, 15-amp electrical supply is
required.
30" (76.2 cm) and 36" (91.4 cm) Range Hood
Installation Clearances
Calculating Vent System Length
To calculate the length of the system you need, add the equivalent feet
(meters) for each vent piece used in the system.
7" (17.8 cm) Round Vent System
Vent Piece Round
45° elbow 2.5 ft
(0.8 m)
90° elbow 5.0 ft
(1.5 m)
7" (17.8 cm) wall cap 0.0 ft
(0.0 m)
3¹⁄₄" x 10" (8.3 cm x 25.4 cm) 4.5 ft
to 7" (17.8 cm) (1.4 m)
3¹⁄₄" x 10" (8.3 cm x 25.4 cm) 5.0 ft
to 7" (17.8 cm) 90° elbow (1.5 m)
Example vent system
Wall cap
7" (17.8 cm) round
90˚ elbow
2 ft (0.6 m)
6 ft (1.8 m)
Maximum Recommended Length = 50 ft (15.2 m)
1 - 90° elbow = 5.0 ft (1.5 m)
1 - wall cap = 0.0 ft (0.0 m)
8 ft (2.4 m) straight = 8.0 ft (2.4 m)
Length of 7" (17.8 cm) system = 13.0 ft (3.9 m)
VENTING METHODS
Vent system can terminate either through the roof or wall. Use 7"
(17.8 cm) or larger round vent with a maximum length of 50 ft
(15.2 m) for vent system.
NOTE: Flexible vent is not recommended. Flexible vent creates both
back pressure and air turbulence that greatly reduce performance.
Roof Venting Wall Venting
A. 7" (17.8 cm) round vent
through roof
(purchased separately)
B. Roof cap with damper
(purchased separately)
C. 18" (45.7 cm) min. to
24" (61.0 cm) max. above the
cooking surface
A. 7" (17.8 cm) round vent out
the top and through the wall
(purchased separately)
B. Wall cap with damper
(purchased separately)
C. 18" (45.7 cm) min. to
24" (61.0 cm) max. above the
cooking surface
A
B
C
A
B
C
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
PRODUCT DIMENSIONS
1"
(2.5 cm)
6⁹⁄₁₆" (16.7 cm)
18⁵⁄₈"
(47.3 cm)
29¹⁵⁄₁₆" (76.0 cm) or
35¹⁵⁄₁₆" (91.0 cm)
1¹⁄₂"
(3.8 cm)
⁷⁄₈"
(2.2 cm)
4¹⁵⁄₁₆"
(12.5 cm)
⁷⁄₈"
(2.2 cm)
9"
(22.9 cm)
A
. 18" (45.7 cm) min. clearance - upper cabinet to countertop
B. 18" (45.7 cm) to 24" (61.0 cm) suggested max. - bottom of range
hood to cooking surface
C. 30" (76.2 cm) min. cabinet opening width for 30" (76.2 cm)
models and 36" (91.4 cm) min. cabinet width for 36" (91.4 cm)
models
D. 13" (33.0 cm) cabinet depth
E. 36" (91.4 cm) base cabinet height
A
B
C
D
E
Ref. W10400320B