Amana, Caloric and Modern Maid Fault Codes
!
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power and gas supply to oven before
servicing, unless testing requires power and/or gas.
16
16023509 ©2004 Maytag Services
PRODUCT(S): FREESTANDING, SLIDE-IN, DOWNDRAFT RANGES AND WALL
OVENS EMPLOYING ELECTRONIC RANGE CONTROL (ERC) WITH
SEPARATE RELAY BOARD
MODEL(S): AMANA BRANDS (E.G., ARDS800**, AGDS901**)
The ERC is capable of detecting certain failures within the control, temperature sensor and door latch.
NOTE:
Refer to the appropriate Service Manual for detailed service instructions
.
Fault
Code
Problem Component(s) to Check
DOOR
displayed
when
baking or
broiling
Door latched, failed latch switch, or open in wiring.. Ensure door is not latched, check latch
switch connections and ohm wiring.
If ok, replace latch switch.
LOCK
displayed
when NOT
cleaning
Sensor resistance too high or shorted wire lead...... Check sensor resistance and wiring.
F1 Failed component in ERC system............................ Check all components and wiring.
If ok, replace control.
F2 Sensor resistance too high ...................................... Check sensor resistance and wiring.
F3 Open sensor or sensor circuit .................................. Check sensor resistance and wiring.
F4 Shorted sensor or sensor circuit .............................. Check sensor resistance and wiring.
F5 Failed component in ERC system............................ Check all components and wiring.
If ok, replace control.
F6 Failed component in the ERC system or
fluctuation in 60Hz power source.............................
Check power source before replacing control.
F7 Shorted or sticking key(button) ................................ Check glass alignment, key (button)
movement.
F8 Failed component in ERC system............................ Check all components and wiring.
If ok, replace control.
F9 Door latch supervisory circuit problem..................... Check door switch(s).