Jenn-Air, Maytag and Magic Chef Fault Codes
!
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power and gas supply to oven before
servicing, unless testing requires power and/or gas.
4
16023509 ©2004 Maytag Services
PRODUCT(S): LARGE CAVITY RANGES AND “D” SERIES WALL OVENS (cont.)
MODEL YEARS(S): 2003 TO PRESENT (cont.)
Fault
Code
Problem Component(s) to Check
3D41 Meat probe shorted........................................................
(single cavity or upper oven)
Ohm meat probe and check for shorted harness.
If ok, replace control.
3D51 Meat probe not calibrated ..............................................
(single cavity or upper oven)
Replace control.
4D11 Door switch position error, opened when latch locked ..
(single cavity or upper oven)
Check door switch and ohm door switch wiring.
4D12 Door switch position error, opened when latch locked ..
(lower oven)
Check door switch and ohm door switch wiring.
4D21 No/low cooling fan rotation (no RPM) ............................
(single cavity or upper oven)
Check connection at cooling fan. If ok, replace
blower. DO NOT REPLACE CONTROL.
4D22 No/low cooling fan rotation (no RPM) ............................
(lower oven)
Check connection at cooling fan. If ok, replace
blower. DO NOT REPLACE CONTROL.
4D31 Cooling fan state error (states on when fan off) ............
(single cavity or upper oven)
Check all fan connections.
If ok, replace control.
4D32 Cooling fan state error (states on when fan off) ............
(lower oven)
Check all fan connections.
If ok, replace control.
4D41 Cooling fan rotation over speed.....................................
(single cavity or upper oven)
Check all fan connections and check for airflow
restrictions. If ok, replace cooling fan.
4D42 Cooling fan rotation over speed.....................................
(lower oven)
Check all fan connections and check for airflow
restrictions. If ok, replace cooling fan.
4D51 Door switch circuit failure ...............................................
(single cavity or upper oven)
Check connections and wiring.
4D52 Door switch failure (lower oven) .................................... Check connections and wiring.
9D11 Latch will not lock...........................................................
(single cavity or upper oven)
Check door lock connections.
If ok, replace door lock assembly.
9D12 Latch will not lock...........................................................
(lower oven)
Check door lock connections.
If ok, replace door lock assembly.
9D21 Latch will not unlock.......................................................
(single cavity or upper oven)
Check door lock connections.
If ok, replace door lock assembly.
9D22 Latch will not unlock.......................................................
(lower oven)
Check door lock connections.
If ok, replace door lock assembly.
9D31 Latch both locked and unlocked ....................................
(single cavity or upper oven)
Check door lock connections.
If ok, replace door lock assembly.
9D32 Latch both locked and unlocked ....................................
(lower oven)
Check door lock connections.
If ok, replace door lock assembly.